Prius (2004-09) :: Blower Motor Stopped Coming On All The Time
Mar 10, 2013
2004 Prius, 135,000 miles.
About a month ago, the blower motor stopped coming on all the time. A quick whack under the glove box fixed it when it didn't start. Then about a week after that, I felt like the AC wasn't really warming when needed. This may have been true earlier, but it hasn't been that cold around here, so I wouldn't have noticed, perhaps.
About a week ago, I start hearing what I might describe as a rattling kind of noise I had never heard before sometimes under hard acceleration. Not always. Didn't hear the noise tonight, for example. Of course, then, tonight, on the interstate, the warning light pops up for just long enough for the temperature indicator to flash up. It quickly disappeared, but in the remaining two minutes I was driving, it flashed up briefly twice more.
Now, in digging around on this topic, I've read about issues with the inverter coolant pump, and that there was a recall. How could I find some information on this recall? I don't remember ever having it changed, so I'm just curious what I might need to say to get that swapped out under a recall if appropriate.
Also, based on what I've said, does it seem likely that the issue is with that pump? It sure seems to fit the bill, but who knows. I'll be bringing the car in ASAP but I'd naturally like to be armed with as much information as possible.
View 2 Replies
Advertisement
I noticed that I have an unusual "rumble" noise coming from the location of my ac blower motor when it kicks in full blast. When the air temp comes down a bit and the AC slows down or if I switch the ac off full blast under climate control, the noise goes away. I have never noticed this before and am wondering if it is my ac blower motor starting to fail.
View 3 Replies
My 2004 camry LE (235K miles) has had a noise associated with the blower for several months. The blower worked fine on all settings but had a subtle noise that was between a purr and a click. It's constant, fast-paced, rhythmic and rises in pitch as the blower setting is changed. Hot or cold settings don't make a difference. The closest I can approximate is the sound made when kids put (or used to put) playing cards in the spokes of their bikes.
However in the last couple months the blower has stopped working intermittently. Sometimes it will come back on if I went over some railroad tracks or a hard bump. If I turn the car off the blower may not work when it's restarted. The last couple days it's stopped doing even that, and since there's snow on the ground it has become an issue! The fan setting doesn't make a difference, high or low.
View 4 Replies
Recently my a/c in my 2007 prius has been on the fritz. Some days it chooses not to blow any air at all. Others it will blow upon start up with cool air. I just took a road trip and it didn't work for 2 hours then magically came on blowing cold air. I took it in to the local shop to see if they could figure out the issue. To my disappointment, all the "parts" appear to be in good working order. The technician said that the electrical system just wasn't getting to the blower motor and that I should take it in to Toyota.
View 4 Replies
I am struggling with it, and need to get it done - by myself, as I can't afford a service job. I am handy, and comfortable doing it, But I am confused about how to get into the blower housing.
View 4 Replies
Turning the fan knob yields no results. The AC compressor does kick in as I can feel it when I turn it on when idling, so the knob appears to work. The blower does not move air.
I checked the fuse below the steering wheel and the fuse makes a complete circuit although the edge looks a bit darkened. Other fuses from working devices look the same and I took a spare 10A fuse from the designated area and inserted into the blower motor fuse location - still nothing.
I will also inspect the relays/fuses in the engine compartment to see if anything in there looks blown that's related to the blower motor. Hopefully it will be something simple, but probably not...
I will need to take it in to get it looked at and fixed, and this is probably not under warranty since vehicle has 56k miles... while I'm there I'll have a transmission fluid exchange done as well and I was planning on getting some body work done.
My bumper was torn off from the fact that it sits low enough that sometimes it would go over the parking stump. Well, it eventually got caught really bad and tore it off. Now the tab where the screw goes to secure the bumper has sheared off so it just hangs. Also, the tearing action from the parking stump caused the inner fender to come off and rub against my tire while driving, tearing it into shreds from the friction.
View 7 Replies
I have a Full Size 93, 5.8L Van. The blower motor has stopped working. I have checked the fuzes, ok. I have checked the Power Distrubution Box, ok. I do have power to my Aux (rear) blower. I have hot wired my blower motor, it works. I have no power to the blower motor, thermal limiter, or to the fan control switch on the dash. (Like I said, the Aux on the dash works). What else is there?
View 14 Replies
blower motor was intermittent on my 08 prius, now only works when i spin it. Looking for a pdf or instructions on replacing it myself?
View 1 Replies
I have started to have very intermittent problem with the blower fan. When I turn the fan on or auto, no fan blows.
If I hit the dash, over top of the display screen it will engage and start blowing.
2007 with 115k miles. I assume this is the blower motor dying a slow death.
I also assume this is not a DIY and will be expensive to fix.
View 7 Replies
I own a 99 Suburban 1500 5.7. The front blower motor stopped working on all speeds so I replaced the resistor, it still did not work. I then replaced the speed selector switch and it started working fine. Three days later I smelled a slight electrical burning smell and the fan stopped working again. I plan on replacing the switch again to see if that is what went bad. Whats causing this to happen? Maybe the motor is going bad and causing the switch to short?
View 6 Replies
My blower motor in my Jetta recently stopped working. When I turn on the blower it works for 10 seconds or so then slows down and dies. Is this a blower motor or resistor problem?
View 1 Replies
Got a 2008 Hyundai Accent. Yesterday, the blower motor just stopped working. I had just started it up, the heater came on for about five seconds. There was no noise, no funny smell, nobody had done anything to it. It just stopped. I checked the ac fuse and it looked fine. I looked in the fuse box under the hood, and I'd like to check the fusible link for the blower motor to see if it has a problem. Is this something I could do and how? Also is there anything else I can do to diagnose the cause of the problem?
View 2 Replies
The air conditioning blower motor stopped working this past summer (worst timing ever). I took it out, put it back in, and it worked again for a day before dying for good. So, I ordered a new one and replaced it. The replacement was working fine for about 5 months, but it then began exhibiting the same problem as the original: it wouldn't come on until after I'd been driving for a while. The new unit never made any unusual noises while running (the old one got noisy just before I replaced it), but now it isn't coming on at all. I find it hard to believe that the replacement blower motor has failed after only 5 months. What else should I check?
View 5 Replies
My air conditioning has stopped working and the dealer tells me the blower motor has frozen up. This car only has 73k on it. Is this common to the 2005 Touareg or ?????
View 3 Replies
I've read quite a few threads on this subject and came across the resistor, fuses, and relays. I have some fundamental testing procedure questions.
1. To test the resistor, it says to back probe the brown/orange wire to check for voltage. So I'm assuming I would hook up my positive lead, here?
Do I really need to hook up the black lead all the way to the negative terminal on the battery? Just with a long extension? Or is there somewhere else I can hook the black lead to? (I know, how dumb!)
2. I downloaded owners manual, but I can't seem to find a fuse or relay specifically for the blower, so what fuse and what relay is it?
3. In the Haynes manual, it says locate the blower motor relay, in the relay box under the center dash panel, where the hell is that?
4. Do I need to remove the glove box to access the resistor and blower hosting.
5. Anything else I should know?
View 8 Replies
I have a 2008 Prius. The blower for the AC and heat stopped working. I have checked the two AC fuses and they are okay. I used the touch screen diagnostics mode on the touch screen and it appears that the touch screen and the screen switches are working. Any other things to check?
How hard is it to access the blower motor to replace or to check if it is getting power? How much of the dash has to be disassembled?
View 6 Replies
The other day I was driving with the air on high, Since the van is rather old, the compressor is quite loud. All at once the blower and the compressor stopped working at the same time. now I have no heat, defroster, vent plus when I slide the selector to AC. the compressor does not kick on.
View 4 Replies
I have a 2010 Toyota Camry 2.5L. Suddenly the blower-motor stopped working. I looked at the under-hood fuse panel and noticed a few of the fuses in the fuse bus-bar were blown, however I'm not sure how the bus-bar is removed. Is this most likely my blower-motor problem? If so, how do I replace those fuses?
View 6 Replies
Well, let me rephrase that, the AC works but blower motor doesn't. When you put your hand up to the vents, they're cold.
Long story short, I ran my AC on MAX on way home from work, driving time of approx. 35 minutes. I got home, showered, and got back into car to go downtown to store. It was then I discovered that the AC wasn't coming on, and it was still on max. I shut it off and turned it back on, but to no avail. I checked all related fuses, or at least what I think is related and checked my "Taurus Bible" the chilton manual. I swapped out a blower motor relay and it didn't work, but i'm not sure that relay was or was not good, it was out of a '96 E-250 at work.
So now I get out my test light. I pulled the connection from blower motor, connect it and turn on AC and light comes on. Vents are getting cooler. So I get my tool and pull the radio and climate control assembly. I pull the plug to the actual fan connection, the part that connects to the fan switch that controld fan speed. I'm getting nothing there.
Is there a relay I don't know of? I know the AC still works because vents are still getting cold, but I can't get air to move. A LONG time ago it did this but "corrected" itself. What is my next step? I'm not sure what to check next and my repair manual is leaving me in a boat with no oars.
More details of car:
1996 Ford Taurus 3.0 V6 Vulcan motor, 8th VIN is UAUTO188,000 miles
White 4 door gray interior 3 car seats
GoodYear Tires inflated to : 33lbs LF34lbs RF36lbs RR35lbs LR
View 1 Replies
My HVAC blower motor stopped today while the wife was driving the F250. I thought I should swap relays (with the heated mirror relay - same Ford Part Number) to rule it out or identify it as the culprit. However, since these are close to the firewall, I have a hard time getting the grip and leverage to pull the relay out of the Battery Junction Box (BJB). How to make this a bit easier?
View 5 Replies
My girlfriend has a 2005 accent and recently the blower motor started working intermittently.. After a couple of days of it coming on and off it now wont come on at all.. After checking the 30amp fuse under the hood, and the relay they all seemed to be in good shape, I even swapped them out with other fuses and relays to make sure that wasn't the problem. I checked for power at the Motor and it has 12 volts going to it when the fan switch is on.. so I pulled the blower motor itself and connected it directly to a 12 volt source and it worked, eliminating the possibility of the motor itself being seized. Now I read up on a few sites on how to check the resistor, so I did a few continuity tests on the resistor itself and didn't see anything out of the normal.. What I should check next or what the actual values on the resistor check I should be reading..
View 1 Replies