Ford Super Duty (1999-2016) :: 2000 - A/C Blowing Through Defrost Vent?
Jan 10, 2014
I have a 2000 f250 4x4 7.3 diesel. I had problems with my a/c and controls for sometime now. my a/c was blowing threw the defrost vent. I was told my blend door was bad. I bought a new blend door installed it,still doing the same thing. I was told to check my vacuum lines. I check them, they were bad. I replace my vacuum lines and my vac pump as well. that fixed my problem blowing threw the defrost vent. I can control my air flow from floor,dash vents and defrost vent. the problem I have, I not able to control my temperature when I turn my center from red to blue. It blows hot air and the air that is coming out of the vents isn't very strong at all.
View 1 Replies
Advertisement
My husband and I have 3 Excursions, V10, 6.0, 7.3 and I have a 6.0 250 crewcab. 3 of the 4 now blow air or heat from just the defroster unless your going at a slow speed.
View 2 Replies
2006 F250 5.4 - While driving ac changes from vent to defrost on it own..let off gas and it will change back to vent. I replaced vacuum can under hood.. no luck.....
View 1 Replies
I have a 2012 F-350 SRW with a 6.7 diesel. The other day I went to push the defrost switch and noticed it does not work. All the lights work in the switches, and the temp control works, but no matter what I push, defrost or floor, it stay in the vent only. Anything I can check??
View 1 Replies
I have a problem with my vent selector on my truck. It's a 2005 f350 lariat. The vent is stuck on defrost, some times after a few mins I can get it to switch to floor but not always. I have replaced the pump, checked tank for cracks, disabled and plugged the auto hubs. The pump will shut off so I assume it's not a leak. I believe it's in the switching unit, can these be repaired? I found a lot of dust and dirt in the vac tank that had been sucked through a bad hub. I think it may need to be disassembled and cleaned. I have seen videos showing how to replace the orings in the older units. Are the newer style remote ones the same?
View 5 Replies
I have followed the vacuum lines but don't see any holes or cracked lines. I dont have the ESOF hubs so that is ruled out. Also checked the connector on the vacuum pump to make sure it still had power. Everybody says that when I turn the key to acc I should hear the vacuum pump running. I don't or do I feel it moving. Am I on the right track? I don't want to replace if not bad. Do all vacuum pumps run on keyed power? I honestly don't remember hearing it run before but that doesn't mean anything with my memory.
View 8 Replies
1999 F250 7.3 4x4 switch on dash with manual hubs. No visual vacuum hoses cracked.
Not sure what this component is but when I wiggle the wire at the orange cap a small motor kicks on.
View 3 Replies
I have a 2008 F350 and there is nothing blowing out of the vents or defrost for AC or heat. It doesn't matter what fan speed is set. Would this indicate a blower motor? Where exactly is it located and how to change?
View 8 Replies
The A/C on my 05 F250 6.0 recently would not blow out through the vents. So, I replaced the vacuum pump and the reservoir tank. Once I replaced them the A/C still starts through the defrost vents but, after a minute or so starts to blow through the vents. I also noticed that the vacuum pump never stops running. Is this normal or is there something else I need to look for?
View 5 Replies
My 2005 F-250 6.0 liter Diesel FX4 Lariat is blowing AC through defrost only all the time. I have manual locking hubs and when I engage 4x4 it works perfectly through the ESOF switch. So I am assuming the vacuum pump and lines to the hubs are in good working order but there is possibly a cracked line or fuse blown? I've only had the truck for 2 days and it just happened after purchase. I'm a little unfamiliar with checking vacuum but have done reading and I believe I can do it. I am going to get a manual hand pump and pump to 20lbs and loss shouldn't exceed 1lb per minute. I just need to know which direction to look. Everyone else had their 4x4 not working and I seem to be the only one posting that has ESOF 4x4 capability when the defrost only issue is on.
View 11 Replies
02 F250 with 7.3. When I activate the 4WD, my light comes on, the A/C quits blowing out of the forward vents and goes into defrost and no 4WD. If I sit and wait a bit, the air again blows out the front vents and the 4WD engages. I figure I have a vacuum leak somewhere in the 4WD system. Is there a common place for this to happen or do I need to trace the whole system down? Also my manual hubs has never been turned and of course they won't. I know better than use a wrench so is there a easy way to free them up or just go ahead and disassemble and clean?
View 3 Replies
Haven't been on here for a while. My f250 AC vacuum pump is out. This means the AC being reverted to blowing out the defrost. I have found the defrost/vent vacuum solenoid and zip-tied it open for a vents-only experience. I just realized, without the vacuum pump, there is really no way of determining if it is on recirculate or fresh air. I wish for the recirculate so I don't get someone else's or my own exhaust in the cab. Does the system stay on recirculate without vacuum power? if not what actuator must I zip-tie next?
View 1 Replies
This is something to check, I found the vent line pinched closed on my 2000 F350 when I was trying to find out why it was leaking. When I was under my 2013 installing the hitch I checked it and found the same problem. The clip doesn't pinch it closed right away but it will happen if you don't move the clip.
View 8 Replies
2000 7.3L SD .. The check engine light is on and if you hook it up to the reader it kills the engine and if you replace the lighter fuse it has power and if you hook it up to trailer it blows fuse and no power any...
View 4 Replies
My wifes truck is having some issues right now. Last week I was driving it down the highway, and the gauges all went off, the door buzzer was sounding, and the door locks where going up and down constant when I had my foot off the gas pedal. Found the fuse and fixed it with a replacement, but its down it three times all together since then?
View 9 Replies
My 06 F250 crew with the 6.0 starting blowing the cold AC out the defrost vent and will not switch to the dash vents. It's goning to hit 108 today and stay around 105 for the rest of the week.
View 14 Replies
Got the new truck on Monday and I am trying to figure it all out
The mirror defrost comes on with the rear window defrost, my question here is does the defrost image on the mirror light up when on?
View 14 Replies
I bought a used 99 f250 v10, i went to turn on the a/c today, and it only blows where the defrost is toward the window. it gets cold after awhile, but nothing out the vents, the heat either.
View 9 Replies
About 6 months ago I bought a 2003 F350 King Ranch to tow my toy hauler. Very happy so far. The one complaint I have is this...
The design of the heater / AC control module for this year of truck does not have a separate AC switch. There is not a separate button to turn the AC on and off and with a separate switch to choose which vent to blow the air through. For this year, I think 99-04, the vent selector switch must be turned all the way to the left and there are two AC Options... AC and Max AC. For both of these options the AC only blows through the dash vents.
Is there anyway to upgrade the in-dash unit to allow you to turn on and off the AC compressor while independently selecting, floor, foor / vent, floor / defrost, vent / defrost, etc... for the vents that the AC blows through?
I live in CA and it can get HOT... I would really like to blow the AC through the floor vents and / or the floor vents and the dash at the same time to provide more even cooling throughout the truck. Also, blowing through the floor vents would provide better cooling to the back seats.
View 7 Replies
I have a 2012 super duty with a 6.2 in it. I bought it last winter and noticed no air getting to the defrost vents. Now in the heat, sometimes when I turn the air on, all I get is super hot air like the heater. Sometimes playing a bit will work but not always.
View 7 Replies
My A/C, vent fan (blower motor) keeps going in and out. Does not do it all the time, but when it goes out, it will come back on after a few moments, but will not run full speed. If you try to adjust the speed, it just cuts off again. What is causing this.
View 7 Replies