Ford F-150 - 1997-2003 :: 2001 - Blows Fuse Touching Gas In Reverse
Jun 7, 2013
Got a 2001 F150 XLT 4x4,4.6L, When you start the vehicle it seems to run a little rough you can drive around with it OK. Soon as you put it in reverse,It starts to really run rough..touch the gas pedal and fuse position #30 blows.
This fuse is for : Passive Anti theft Transceiver, Cluster Ignition Coils, Powertrain Control Module, Relay Coil on Plugs, Radio noise Capacitor, ECC Diode.
I have checked cables and connections, all seem ok...Relays are fine. Nothing seems burnt on the cable running from the engine to the exhaust. I don't see any wire breakage in the tilt Column.
Cant find a short if it is one.. Even removed the aftermarket Remote starter from the circuit ... still blowing that darn fuse.... What to check now, or what it could be?
View 6 Replies
Advertisement
97 F150 4.2 auto with Simple trans pan gasket change because it was leaking and now the ignition fuse blows every time I turn the key to the on position. Ran fine before now what? can't pull code with reader with key on or off.
View 4 Replies
I need to diagnose a heat problem. I have a 2001 F150 XL. 4.2L Manual controls. The a/c blows nice and cold, but when you put the heat on its not really hot, blows warm air. I changed the blend door actuator,it got a little warmer. Now that winter is around the corner need to figure it out and fix it. The thermostat, water pump, and coolant flushed before I bought it. Could it be the blend door itself, or is there another actuator I'm missing.
View 14 Replies
I am having a problem with trailer lights and an 03 350. When the truck is in reverse the fuse for travel trailer running lights and tail lights blows immediately. Changing plugs on the truck did not work. Truck has been hooked up to 4 other trailers including another travel trailer with no problems. Our travel trailer has been hooked up to an 08 and a 2011 truck with no problems. Fuse 38 20 amp. 7 post rv plug.
View 3 Replies
I just bought an 01 F150 and previous owner didn't have the manual.
Need a copy of the fuse box diagram for this truck?
I've been surfing the net, and can't find what looks like the right one.
View 10 Replies
When I opened my sliding rear window yesterday the vertical weatherstrip that touches the glass of the sliding section tore off.
Is there a way of repairing that?
View 5 Replies
I am having trouble with my 2001 F-150. Starting yesterday it would not start. At 1st i thought it wa the battery, so i took it off, charged it, put it back in the truck and still no start. There is a clicking noise coming from a relay in the cabin fuse box, disconnected the battery, removed relay to inspect and everything looks good. After plugging it back in, and connecting the battery, the truck still wont start and there is a clicking sound coming from the dash near the radio. Rhis is my work vehicle!!!
View 3 Replies
I was having intermittent fuel pressure problems. I replaced fuel pump and relay and was still having the problem. A figured out that wiggling the 20 amp fuse would cause the intermittent. Looking at the connections for the fuse, I can see one side was damaged. I figured I could pull the connector out from the back and fix the connector, but when I took the back off (see picture) I have a purple wire (labeled 1) going to one side of the fuse and a multi-connector (labeled 2) from one wire going to the other side. My luck, it's the multi-connector side that is damaged.
It Looks like the multi-connector goes to the Black and yellow wire. Instead of replacing the box, I figured I could just create an inline fuse for the fuel pump with the purple wire and splice it into the Black/yellow wire.
I can't see any problem with this, just looking for a second opinion. And I'm not sure how it would effect the relay. I can't find a fuse panel wiring diagram anywhere.
View 2 Replies
I got my first truck about a months ago 2001 ford f150 v8 5.4.. has 155,000 seems to run good.. but about 3 days ago i started to notice that when I am in my driveway ill start it let it idle for say a min or so... then when I go to put it in reverse it will idle up for a lil bit.. it didn't do that till about 3-4 days ago.. other them that everything is fine.. should i get the transmission fluid flushed??
View 7 Replies
Recently got a 2003 f 250 6.0 that has had a little work done on it. Absolutely love it with 1 exception. When I turn on the ac or heat It blows a 10 amp fuse that goes to the blower relay. It was occasionally now it's all the time.Blower ok, fan speed resistor ok. What or where to look.
View 8 Replies
Son has a 2004 Hyundai Santa Fe 2.7 motor. The timing belt broke before we could replace it. Long story short, 24 valves, gaskets, timing belt, water pump, new belt tensioner and new pulleys. The motor is back together. The only problem is when you turn the ignition switch on, it blows the CPU fuse. The only electrical part we replaced was the purge valve.
View 3 Replies
This is for a 2003 GTI, 89,00 miles. Every time I try to use the windshield cleaner the fuse blows for the windshield wipers. I have tried to put in a 25 amp fuse and it worked for a while but still blew. The windshield wiper motor has been replaced.
View 1 Replies
This is for a 2003 GTI, 89,00 miles. Every time I try to use the windshield cleaner the fuse blows for the windshield wipers. I have tried to put in a 25 amp fuse and it worked for a while but still blew. The windshield wiper motor has been replaced.
View 2 Replies
When going down the road, the air blows threw the defrost and on the down hill it comes back to the vent.
View 14 Replies
I took the dive into a new heater core, as the heater was not getting hot. These are the things I did while on my adventure.
1. Before reinstalling the hoses, I blew thru them to make sure of no clogs...water flew out the other hose..no problem..no clog.
2. inspected mix door not cracked or broken...no problem
3.actuator opens and closes ok, I assume, I can hear the motor run and the door thump closed...no problem
4. water and anti freeze level good....no problem
Start vehicle,let warm up, turn on heat.....No Heat...
5. check hoses at core, one is hot ,the other is not....Problem...
1997 f150 4x4 ...
View 14 Replies
My 1999 F250 ld light duty has an AC problem. It only blows cold sometimes. And it doesn't always work when selected to AC or Max AC. It will work on Panel also. When it works it works great. It blows really cold. But it will work fine then I'll come to a stoplight and it will stop sometimes.
View 9 Replies
1998 F150 step side, 4.6 V-8 automatic, 176,000 miles -
Heater begins to blow heat as the engine warms up - heat gauge moves up to normal level - running at speed, suddenly the heater blows all cold, the heat gauge pegs to total hot - the oil light comes on, the engine begins to miss - stop the truck, shut off the motor, wait 10 seconds, start back up and all is normal and away I go. Heater working just fine. Gauges are just fine. Have checked the hoses when it pegged to hot, and they are just warm just as if everything is normal.
Problem is intermittent.
Have changed radiator reservoir cap, thermostat, made sure fluid level and mixture is correct - what else to check? Computer issue?
View 7 Replies
Every time that I hit the brakes, the headlights flash and the horn blows for about 30 seconds. I am guessing that it has something to do with the factory alarm? I do not have a key pad. It is a 1997 F-150.
View 3 Replies
I am having an issue with a fuse in the in cab fuse box, it just falls out. How to get the fuse box down from behind the dash ? If i could get it down I can repair the fuse holder, or something.
View 2 Replies
Why the 30amp PCM fuse located in the under dash panel would blow. Problem started while truck was running and a simple replace of the fuse would it it back alive again. Now fuse is blowing at ignition on. Truck is 1997 F250 LD.
View 7 Replies
I am having trouble with fuse 23 under the hood blowing while driving. I have read several threads on this issue but still no luck. I have removed all 4 02 sensors and ac relay and still about 1/4 mile down the road the fuse blows, and is giving the shift solenoid A shift solenoid B and the torque converter clutch solenoid electrical circuit. I have checked both plugs on the trans, I even dropped the pan and ohmed the solenoids out. I dont know what else to do?
View 14 Replies