Ford Excursion :: HVAC Blower Won't Turn Off


Aug 25, 2016

I'm new and have recently bought my first X. its a 2001 XLT with the 5.4. I really couldn't pass it up with the guy asking under 7K with 104,000 miles and not a rust bucket.

I discovered last night that my blower (at least front) continues to blow when key is out and off. I have played with the key to think its a switch but am not sure. Here's the other part, If I turn the selector to off before shutting the truck off it stays off BUT if i turn it on it will not go back off and stays on....

View 6 Replies

Advertisement

Phaeton :: HVAC Blower Won't Turn Off?

I have a problem that's sprung up all of a sudden and I wanted to run it by you before taking it in to VW. For the past three days or so the blower on my Phaeton's HVAC has been unresponsive to my control, staying on its highest setting permanently, even when I turn off the car.

This of course means that overnight power management takes over and when I get to the car in the morning I have to unlock it with the physical key, the clock has to be reset and I get all kinds of warnings about level fault and system fault. These warnings go away immediately as the car powers up, and everything is back to normal except for the fan.

I've tried resetting all settings on the control unit, but since the fan stays on even when the car is off, I feel like it's not software? The rest of the HVAC settings seem to work fine- I can toggle the vents and change the temperature, just not the blower speed.

View 24 Replies

Santa Fe (CM - 2007-12) :: 2011 Limited - HVAC Blower Doesn't Turn On From Time To Time

Over the past year we have been noticing that the HVAC blower doesn't turn on from time to time. All settings in the control panel seem normal and the fan speed is turned on. Most of the time everything is working normally, sometimes when the car starts the blower isn't working and then starts after a minute of driving. Sometimes I notice the blower isn't working and I turn up the fan speed and after a few clicks it starts working normally for the remainder of the drive. And then sometimes the blower doesn't ever start and I need to turn off and restart the car a few times. When the blower hasn't been working the a/c compressor has been turning on, something in the blower circuit is failing.

There are five possibilities:
The HVAC controller isn't telling the blower to turn on
The power relay isn't always working
There is a wiring or connection problem
The blower motor itself isn't working
The power mosfet is failing.

What needed to be replaced?

View 2 Replies

Ford Excursion :: Blower Motor Wouldn't Turn Off By Itself When Truck Was Turned Off

It started with the blower motor that wouldn't turn off by itself when the truck was turned off. I forgot to turn the fan off one night and woke up to a dead battery. Got my dad to come give me a boost and it would turn but not start and the anti theft light in the dash was blinking fast.

Later in the day I got another boost and it started right up.

This was yesterday... after the last boost and startup I went and got a few things, stopped to get gas... started back up fine each time.

Last night I was greasing zerks and making sure everything in the front end was nice and tight when the abs module started clicking... and the anti theft started blinking and truck wouldn't start. Left it alone and went to bed.

This morning I boosted it and it started fine. Later in the day it wouldn't start again because of the anti theft. Gave it 5 minutes and it started. Stopped to get gas... wouldn't start (anti theft)... started after about 5 minutes.

On the way back home... it's been making this 5 beep, pause, 5 beeps, pause sequence so I pulled it into the garage and turned it off now the locks are locking/unlocking by themselves randomly, the beeping is on and off, anti theft light blinks for a few minutes then goes away only to come back...

I've been told to remove the fuse box under the hood and check to make sure all connections are clean... I've searched and seen possible solutions ranging from a dirty connection to needing a new GEM module and apparently sometimes just a low voltage situation will cause our trucks to act nuts...

View 14 Replies

Ford A/C :: 2002 Excursion - Blower Stay On High And Wouldn't Turn Off

About a month ago I replaced my blower control module. I purchased the module from Rockauto. The first replacement module lasted about a month. I received a replacement because the blower stayed on high and wouldn't turn off. The second module only last one week, the blower once again only blows on high and won't shut off. Both replacement modules were made by Dorman. Could something be killing them or am I just getting crap parts?

View 5 Replies

Ford A/C :: 1995 - HVAC Blower Wiring Schematic

My 1995 Ford motorhome blower does not work. The motor works fine. All threads say to follow the circuits to troubleshoot. That is nearly impossible with wiring harnesses. I need a Ford F- Series HVAC wiring schematic to find ALL of the electrical components, in order to test.

View 7 Replies

Ford - Explorer :: 2008 - HVAC Blower Inlet Blocked?

So I just picked up a 08 STL. I noticed that it doesn't get a lot of airflow out of the vents or floor. I initially thought that it was door actuators. I checked the vacuum at all of them and they all cycled as required.

I also checked the blend door, and the fresh air doors as well. They all cycled as desired. When I was checking my fresh air door with the borescope, I noticed a layer of... insulation maybe? on top of the inlet for the blower. So I removed the blower, and the picture below is looking up into the housing. Is that supposed to be there? It appears extremely dense, so I am led to believe that's what is causing my flow issues.

If it does not belong, how to remove it? Where is the fresh air inlet on this thing?

Full size : [URL] .....

View 4 Replies

Ford 6.7L Power Stroke Diesel :: HVAC Blower Stopped Working

Just got back from a 1200 mile camp trip pulling an 18K toy hauler. 500 miles into the trip the HVAC blower stopped working. Right after the torrential downpours we had last week. Did some limited checking and found the relay under the hood real hot. Swapped it out with the DEF relay and no luck. All the fuses were good.

This was in the Littleton, MA area. Dragged the truck and camper to a Ford dealer who had no interest - "make an appointment for sometime next week". Dragged the trailer to another Ford dealer who was equally not interested. From here we towed the 130 miles to our next stop.

You really miss your HVAC when you have to drive with all the windows open and two fur dropping Golden Retrievers in the back seat. The fur just circles around and ends up either in your eyes, nose or mouth.

Next day I was off in search of a repair. 20 or so miles north I find the next Ford dealer not intrested. Now I'm pissed and rant a little bit at the dealer.

I did almost 20 years in new car service, all highway dealers. Not once did we turn down a vacationing family on the road with vehicle troubles. We have even done engines and transmissions for travelers broken down.

60 miles to the next dealer in Laconia, NH, Irwin Motors, Ford, Lincoln and Toyota.
Same initial story “we are really busy and backed up”.
But, if I was willing to wait a little bit they would see what they could do.
45 minutes later I get the news that I need a blower motor and it is ordered.

No problem. I show up at 2, park the 5<sup>th</sup> wheel in the lot and at 3:30 we have a free wash coupon and we are on our way. And the service people couldn’t have been more pleasant to deal with. Even the techs came out to visit the dogs as we were walking around. 5 stars for Irwin Motors.

View 14 Replies

Ford A/C :: 2009 Escape - HVAC Blower Motor Do Not Seem To Move Any Air On Speed 1 And 2

I bought my youngest daughter a used 2009 Ford Escape (out of warranty) a week ago. Manual HVAC controls, 3.0 V6, AWD, 73K miles. The HVAC blower motor do not seem to move any air on speed 1 and 2. However speeds 3 and 4 appear to operate normally. Speed 4 noticeably puts out more volume of air then 3. Each 3 and 4 operator what seems to be normal speeds for their setting.

I would normally suspect resistor but my experience is usually that you have all or nothing not it's partially working like this is. I don't mind throwing a new resistor in there and trying it but I rather come up with a better way of troubleshooting it then throw parts at it.

View 5 Replies

Ford F-150 (2009-2014) :: HVAC Blower Noise In Cold Temps

Was 7 degrees F out this morning. Went to turn on the defrost and heard this: (may need to turn up audio a bit)

2013 F150 HVAC blower noise in cold temps - YouTube

There was some snow/ice buildup under the "grate" that sits above that I imagine is the air intake for the blower. Hoping that it was just Ice buildup that will thaw out.

I ended up having to turn it on because the condensation on the windshield was becoming a safety issue when I drove into work. Motor made quite a high pitched wine. Better that than slid into a car.

View 1 Replies

Ford Escape / Hybrid :: 2010 - HVAC Blower Motor Only Seems To Be Working On 3 And 4 Position?

Blower motor only seems to be working on the 3 & 4 position? Resistor bad? What is the location?

View 1 Replies

Phaeton :: HVAC Air Blower Always At Max

Today something strange happened to HVAC. The air blower is always set at full speed regardless of the HVAC setting, mode, etc. The fan speed control does nothing now, even turning the HVAC off is not working.

The only way is to shut the ignition, even when the ignition is off, the solar ventilation function works even when it is set to off!

I believe that a relay or a contractor from the solar ventilation is jammed but not sure because I've re coded the roof electronics to "no sunroof" at all but still didn't work.

View 12 Replies

Ford Escape / Hybrid :: 2006 - Fuse 26 Keeps Blowing / HVAC Blower Motor Turned Off

I have a 06 Mercury Mariner and this past week fuse #26 keeps blowing turning the HVAC blower motor off. I replaced the blower motor since i had one already in the garage and same thing is happening. The AC will run for awhile and in about 10/15 mins the fuse will blow. Fuse #26 is the Climate control system mode switch, are these known to go bad? Is this the part I should replace or look for other problems IE compressor?

View 2 Replies

Ford Super Duty (1999-2016) :: F250 - HVAC Blower Motor Stopped While Driving

My HVAC blower motor stopped today while the wife was driving the F250. I thought I should swap relays (with the heated mirror relay - same Ford Part Number) to rule it out or identify it as the culprit. However, since these are close to the firewall, I have a hard time getting the grip and leverage to pull the relay out of the Battery Junction Box (BJB). How to make this a bit easier?

View 5 Replies

Accent LC (2000-05) :: HVAC Blower Won't Shut Off

2005Accent. First question: Just replaced blower assembly last week and worked normally. Now the blower operates even with the car off and the no keys in the ignition. The fan speed selector still switches between all speeds whether it's running or not, so it doesn't seem to be the resistor.

View 4 Replies

Phaeton :: Low Volume Buzz Whenever HVAC Blower Running

A few days ago I noticed that the front tweeters were producing a low volume buzz whenever the HVAC blower is running.

Let me explain it: The HVAC system is in auto, I am listening to a CD track and the track finishes. At the very short period that it takes for the new track to play I can hear that distinctive buzz coming from the front tweeters. If I now turn off the blower and repeat the same sequence I cannot hear the buzz.

I would say that the buzz frequency is not correlated to the blower speed, but it is difficult to assess because of the increased volume of the blower at high speed.

I have checked the pins and the wiring at the amplifier connectors and they are all sound, so I am wondering if the smoothing capacitor that sits at the plenum chamber fuse box might be the culprit.

View 2 Replies

Prius (2004-09) :: 2006 - HVAC Blower Motor Replacement?

I am struggling with it, and need to get it done - by myself, as I can't afford a service job. I am handy, and comfortable doing it, But I am confused about how to get into the blower housing.

View 4 Replies

Chevrolet - Tahoe :: 2003 - HVAC Blower Switch Only Works When Put It On Highest Setting

My HVAC blower switch only works when I put it on 5 (the highest setting). What needs to be replaced (besides the whole truck)?

View 4 Replies

Ford Excursion :: Rear HVAC Seems To Only Blow One Temperature

Picked up a 2001 Excursion a few weeks ago. Trying to sort out some of its issues. The rear HVAC seems to only blow one temperature... Luke warm. Front A/C and heat work fine. I checked the temp blend actuator and it seems to work fine. The rear expansion valve gets cold and there is condensation that drips from the rear. What else I can check?

View 14 Replies

Ford Excursion :: HVAC - Air Doesn't Divert To Any Specific Vents At Front

I have a 2000 Ford Excursion v10 that won't divert air through any vent. Blower motor works through all speeds from low to high. I hear air being pushed around but doesn't go to any specific vent (barely comes out defrost and front vents though). Temperature Blend door and actuator for door work fine. Vacuum tested and no leaks. Opened up the glove box to expose heater core, noticed the vacuum actuated rod that sits to the left of the heater core is sloppy and barely moves up and down when controls are changed. I believe there is another vacuum actuator in the dash somewhere closer to the driver's side that may pose as a fault as well.

View 6 Replies

Elantra MD (2010-15) :: HVAC Blower Noise / Metal On Metal Rubbing

My Elantra's HVAC fan has always been a quiet thing, even on 3.....we won't mention level 4 and the fact it sounds like a 747 at takeoff.

I kid you not, the very evening I hit 60,000 miles and the general warranty expired, the blower motor started making noise like it was throwing a bearing and definitely sounded like some light metal-on-metal rubbing. After I became irritated at this, the noise went away and didn't come back until just a few weeks ago. I could make it stop by smacking on the bottom of the fan assembly a few times but I want a more permanent solution.

Tonight I dropped the blower out which was stupid easy except for the fact you're upside down in the dark with your head in a hole. But three screws and an electrical connector later, I dropped the assembly to find no serviceable components. I mentioned this to friend of mine who's into Volvos suggested spraying some lithium grease on the hub of the blower and letting it run long enough to quiet it down. I'll do this over the next few days and report back but part of me thinks a new blower may be in my future.

View 53 Replies





Copyrights 2005-15 www.bigresource.org, All rights reserved