Ford 7.3L Power Stroke (1999-2003) :: 90 Degree Elbow Not Fitting The Fuel Bowl?
Apr 25, 2017
Trying to fit my edge fuel pressure sensor. I have a 90* fitting from Diesel O-rings and I can't seem to get the 90 elbow to turn all the way down before it makes contact with the fuel bowl housing. I'm using the drivers side port, should I use the passenger side port? would it have more clearance than the driver side port?
My instinct is to crank it all the way down then tighten the nut, should I just screw it in until it makes contact then tighten the nut? I was worried it wouldn't have enough threads in contact to seal as well as it should and leak.
View 3 Replies
Advertisement
New to me early 99 (4/98) f350 7.3 6 speed. Truck started acting up a few days after I bought it. Return line at fuel bowl was leaking, so started there and found a bad seal on the Fpr (unrelated to the fuel leak due to disentegrated compression sleeve). Fast forward through a bunch of parts swapping that still resulted in miserable lift pump pressure readings, I pull the sending unit out of the tank, expecting to find a plugged screen.
Well, there was in fact a plugged screen... Attached to the bottom of an in-tank pump. How did that get there?!? Everything I've read says there should only be a pickup tube??? Should I get a new sending unit from a junkyard and do the hutch mod or???
View 9 Replies
I want to build a fuel bowl delete/regulated return fuel system for my 2000 f250 . I would like to make a really neat kit and attach all products used so people that want to build their own would have a useful source. I understand that it will probably cost the same but I want to design my own and route it the way I want . I have 3/8 1/2 5/16 and 1/4 stainless tubing as well as a bunch of unions and 90* 45* fittings and a couple tees. What size is the ports for the fuel lines that go into the four corners of the heads . I am a pipe fitter pipe welder by trade so this is basically a mini version of what I do everyday at work. Looking for some size details of the head port sizes so I can get the correct fittings?
View 3 Replies
I've had an engine oil leak for some time. Recently I've had to add about a quart a month. I got some fluorescent dye and added it to the engine oil last time I added a quart. Ran the engine for a few weeks. Then cleaned the engine valley with cleaner and hot water.
Tonight I investigated the top of the engine with a black light. To my surprise, the oil leak is coming from the fuel bowl, right around the drain valve. I can clearly see about a drop every 3 seconds of fluorescent yellow liquid falling into the valley below and yellow all around the valve.
I expected a leak from the HPOP not the fuel bowl. Do I have a bigger problem? Is engine oil getting into the fuel? I plan to replace the seals in the fuel bowl, but not until I know whether I have a larger problem to address.
2001 F250 Crewcab, 220,000 miles
View 11 Replies
I've thought I smelt diesel fuel on an off for a while, but never found the source.
Tonight, 17 degrees out I have fuel in the valley and it appears as if the back of the drain valve is wet.
A fuel bowl rebuild is on the short list. Is this typical, the cold weather brings the issue to light?
View 10 Replies
Had the ole factory fuel separator/bowl drain start leaking on me about a month back. So i ordered and installed a new one, issue fixed. Well last night the fuel leak started again, I looked everywhere and i cant see anywhere else it may be leaking at. I felt the underside of said piece and it didn't feel wet, but the valley is full of fuel.
I got in there and tightened the 4 bolts down some more, they were tight but i got a some turns on em and am hoping i either didn't tighten it down enough or they maybe backed out some. Now just gotta see if that solves the problem, again.... the replacement is a doorman, the o-rings were bigger/thicker than the factory orings on the old part, of which the o-rings were shot.
Like I said once i replaced the part the leak stopped for 3 weeks until last night. If the tightening of the bolts doesn't solve it where should I look next? I have an FRX mod but i checked all that and its dry as a bone around all the fittings by the bowl and the heads. No indications of leaks anywhere around any of the FRX assembly.
View 14 Replies
I just changed the drain valve on the fuel filter bowl. All went well and no more leak, but now I am getting an "emission system" warning light.
After I replaced the valve, I filled the fuel bowl with diesel fuel. Was there any other priming that needed to be done (if any)? What the emission system warning light may mean?
2002 F250 7.3L 4x4.
View 2 Replies
I had just replaced my the fuel pressure regulator in the fuel bowl because it appeared to be leaking from where the FPR is, now with the new FPR , it is no longer leaking from there but now leaking (fast steady leak while running) from the fuel rail outlet fitting... How do you replace these, why all of the sudden it started leaking there ???
View 9 Replies
2003 6.0 no start. turn the key to on and nothing happens. dash lights up as it should but I don't hear the glow plugs cycle and no fuel gets into the upper fuel bowl. turn the key over and nothing happens. No starter click nothing. tried the starter wire to the battery trick and it cranks but does not kick over. checked ficm wires and they are secure as well as the injector wire on the intake manifold. it is the original ficm.
View 6 Replies
I read 18lbs for the water pump but it took a cheater bar (perhaps due to corrosion) to get the water pump lower elbow bolts off.
On reinstallation, what should the lower elbow bolts be torqued to? Checked the sticky (Ziggy's Torque Specs) but didn't see the specs for this item.
View 2 Replies
In my motor build I'm replacing the HPOP fittings in the head. Do these need any sort of thread locker to secure?
View 2 Replies
Last couple of days I've been chasing a small oil leak. Finally figured out it's coming from one of the hoses connected to the lower part of the hpop (hpop hose). Leak is coming from the fitting connected to the lower part of hpop. Do I need to replace the whole hose and fitting? Just the fitting? is there a replaceable washer or oring?
View 10 Replies
Should the upper fuel bowl be empty after sitting for 30 minutes?
I believe no. Which would indicate to me a stuck open injector which Iv been suspected of. Iv been trying to track down a miss that I have and Iv been suspicious of a bad injector but ain't been able to pinpoint which one yet.
View 8 Replies
2004 F550 with a 6.0. I had to clean out my fuel tank, replace the HFCM and filter on top of the engine. When I start the truck it will run for 30 seconds or so, start running rough then die. I opened the cap on the fuel filter housing on top of the engine to make sure the fuel was getting there. I turned the key on and the fuel bowl quickly filled up.
After a short time however, the fuel drained out. To where I do not know. I don't think this is normal as every time I've changed the upper filter on a 6.0 it is always full of fuel. Why could this one be draining out and could that be the issue why the truck dies after starting and running for a short period of time. I changed the o-ring on the cap and the new HFCM was purchased from Ford.
View 13 Replies
I have an isspro gauge and did the blue spring about 5 years ago. Since then my fuel pressure is in the 65psi range.
Last week it dropped to 50-55 normal driving and I figured the HFCM was on it's way out (195,000 miles). Replaced the HFCM and the pressure was a bit higher, but not back to it's usual range. Then pulling the boat home from the lake a couple days ago, I saw it at 45psi. On a couple hills it went as low as 40 psi, so I was getting gripped...coasting downhill it only went back up to 50 psi and no higher. Got 'er home and currently not driving it.
In garage with Key On Engine Off, during injector buzz, I can hear a hissing/air noise at the upper filter bowl. Also, the bowl drains empty once the pump cuts off and the sound of air stops too.
I am hoping it's a regulator issue, but I don't know if they are known to wear out or go bad, or if something else in the upper filter housing went bad. So I ordered a new upper fuel filter housing which also has the oil filter tower attached and I'm assuming that these new units would come with the blue spring upgrade already done.
I can check for codes tomorrow when I bring my computer home from work, so I haven't checked for codes yet. I pick up the new filter housing tomorrow and will periodically check back here during the day tomorrow.
Also, while I'm at it: the new HFCM doesn't have the heater. Can I just leave the old connector from the harness un-connected to anything?
View 12 Replies
So my 7.3 started sputtering and lost power, died on the side of the road. I wasn't far from home put about 8 gallon of diesel in the tank with a couple of fuel jugs and it fired right up.
Gauge was reading 1/8 of a tank and low fuel light did not come on. (low fuel light comes on when you start) Gauge came up to about 1/2 after putting fuel in.
What happened? Gauge was always reliable and low fuel light always did work. Only work done to fuel system was had new tank straps put on a couple of months ago.
View 13 Replies
01 7.3. Cranks, won't start. Tank was at 1/4 but is full now. The lift pump runs, I can feel and hear that the motor is spinning when I cycle the key. I removed the fuel filter and cycled the key and get no fuel into the bowl. It looks like the lines are stainless from the pump to the tank so I doubt it is sucking air. I pressurized the tank with a shop vac and I get fuel coming into the filter housing. Am I missing something obvious? I have never seen an electric pump that would run and not pump fuel. I removed the suction line at the pump and don't feel any suction there.
View 14 Replies
2003 F-350 - 7.3. With the key in the on position there is zero voltage to the fuel pump. Fuel pump fuse is good. I traced the red with black tracer wire from the pump up through the firewall and to the safety inertia switch. The switch has continuity so it's OK. Then from the safety switch I traced the green with yellow tracer wire to a fuse block plug connector. Then I checked continuity from that connector out to the #40 fuel pump fuse and it's open.
So I then i checked from the fuel pump fuse to all the back connections on the back of the fuse block and there was no continuity to any of them. So I removed the back cover off the fuse block to expose any issues. I found two board mounted relays. Now, from the fuse I get continuity to one of the relay connections. So did Ford hide the fuel pump relay and make it non replaceable? Also if this is the pump relay then what circuit energizes it? I need to make sure before I replace the fuse block.
View 14 Replies
I have a 2003 F250 and dont have power at fuel pump, or fuse #30. I put power directly to fuel pump and it worked and truck fired right up.
View 13 Replies
Low power on my 2003 7.3 F350. The truck runs fine but I can tell it is low on power (seat of the pants). I figured it to be fuel related so changed fuel filter and oil with no change. When that didn't work I installed a fuel guage and this what I found. Key on no start fuel pressure 45 psi. Start truck the pressure will get up to 61psi. Under a load it will drop down to the low 30s. I have dropped the tank mixing chamber screens clean and so was the tank. Changed fuel pump and now under a load it drops to the high 30s. Does this sound like the fuel pressure regulator is leaking by and causing low pressure under a load? Truck is stock besides superchips 1705 programer.
View 9 Replies
There was no power getting to the fuel pump on my 2002 Ford F250 73 diesel traced it back to the inertia switch no power in or out but I'm getting power at the fuel pump relay put the code scanner to the PCM and no communication....
View 9 Replies