Ford 7.3L Power Stroke (1999-2003) :: 2002 - Leak Coming From The Top Of Transmission
Feb 15, 2016
I had a leak coming from the top of the transmission. The antifreeze appears to be getting into the transmission because when I pull the stick it's a chocolate/white fluid and both the antifreeze and the transmission fluid are new. So, I am talking to two transmission places, trying to decide which one to go with and what to ask them to install because it seems I have different choices depending on what I want the truck to do. I will be using it to haul dirt and farm items, pull a 20 ft cargo hauler, maybe a rv some day.
The transmission guys are throwing all kinds of lingo out there I don't understand. and the price is anywhere from 2500 to 5000 for the tranny. Also they tell me what is included and what is to be changed out but I don't know if it's "everything". One guy said that the "John Woods" brand of tranny is what I want. Also I think my stock engine is fine. A cylinder contribution test shows only one with an issue and it seems to rev fine. The glow plugs need to be replaced I think. Where I'm getting here is if later I have to replace/rebuild the engine should I get a bigger tranny now?
View 14 Replies
Advertisement
I've never had a drop of fluid leak from my transmission until yesterday. I towed a very heavy trailer (10k or so with tons of tongue weight) about 300 miles and I got back and noticed a decent amount of fluid leaking. The transmission temperature never went over 160 on the drive. I know these transmissions tend to puke oil sometimes, but doesn't that only happen when they overheat, or would a very heavy trailer have the same symptom?
It appears the leak is coming from somewhere near the back of the pan around the gasket. More specifically, it seems the one bolt pictured below is leaking. All bolts are tight and the pan gasket was replaced about 6k ago with the last fluid flush.
View 14 Replies
I have a 2000 Ford Excursion 4x4 7.3 with 230K miles, around 15,000 miles ago I replaced the transmission with a rebuilt 4R100, lately I have noticed a leak towards the back end where the transmission and the transfer case connects. Some of the bolts on the bottom of the pan have ATF on them, some others however do not. I have had to add a quart of ATF in the past couple of days in order for it to engage into drive when going from Park to Drive. I have to rev it before it actually kicks in. I'm hoping the leak is just being caused by a gasket either in the pan or connecting the trans to the transfer case..
View 7 Replies
I have a 2003 Excursion with a 7.3 and 240,000 miles. I have oil leaking around the transmission and the local diesel shop found the pedestal leaking. I installed a new pedestal from Rotomaster Part # A1382205N. It came with new O-rings and turbo bolts. I ran the truck and it began leaking again. Thinking I had pinched an O-ring I pulled it apart again but found nothing. I cleaned and inspected everything and reinstalled. Its still leaking. I used a straight edge to ensure the sealing surfaces were straight.
View 14 Replies
I have a '02 7.3 that has developed a severe oil leak in what seems to be a small line that runs from the drivers side head to the HPOP on the passengers side.
it seems to be leaking at the braket that secures it to the head on the drivers side.
what is this line called and where can i find one A.S.A.P?
View 14 Replies
So after a hot drive yesterday we thought to do some googling about our clutch cycling on and off so fast. Yep, the airgap was out of spec. Fixed that.
Then we added some refrigerant to the truck. The truck is "new to us" and this is our first summer with it so not sure what might've gone on previously with the AC. Didn't take long to find a rather sizable leak. :P
See that metal tube going into the "spongy" area? Yeah, that's where it seems to be coming out. That tube is the only one that's cold, the rest are ambient temp. We fix a lot on our jeeps, but the AC system is naturally a bit out of our wheel house since it's not something you normally tangle with. Is this an easy fix? Or do we need to take it in to get serviced?
View 12 Replies
I've thought I smelt diesel fuel on an off for a while, but never found the source.
Tonight, 17 degrees out I have fuel in the valley and it appears as if the back of the drain valve is wet.
A fuel bowl rebuild is on the short list. Is this typical, the cold weather brings the issue to light?
View 10 Replies
Last year I did some major work on my 02. Painted it, new injectors, 38R, and once it was back together, the transmission went south in a month. Got a Ford reman HD4R100. Shortly after the install, when in reverse, the torque convertor would lock up when you stepped on the throttle. As soon as you let off the throttle, it would disengage. Thinking it was a tranny issue, got another one from Ford. This one has been in the truck for about 9 months. And it seemed fine until about a month ago. It started doing the torque convertor lockup thing in reverse like the last one, but not as often.
Then last weekend it did it every time I put it in reverse. Then yesterday, while pulling away from a traffic light, there was a loud bang, and lost power in the transmission. Once stopped, I found out it has manual 1st and 2nd, but nothing else. No drive, overdrive, or reverse. I personally believe something electrical led to these issues, and ultimately, the transmission failure. I know the truck is not stock, but I do not run it hard very much. When it went bang yesterday, I was not being hard on it. Where to look at what is causing this?
View 14 Replies
2002 F 350 7.3 4x4
Aftermarket gauge will climb to 250 after around town driving of an hour or so or multiple trips within the hour. Not towing. 160,000 miles on odometer. Changed trans fluid at 40,000 mile intervals. Most recently about 1500 miles ago. Most recent change using Mark K's method. Was getting fluid from rear port when I changed fluid. Blew out oil cooler and there did not seem to be a blockage as flow was sufficient.
Still overheating according to autometer trans gauge in test port. No codes retrieved using auto-ingenuity also O/ D light is not flashing. Would like to run torque converter slip test using AE according to wooden things method but TC slip desired and transmission gear ratio is not available under that name in live data meter. AE just updated to most recent version.
I purchased a new tranny oil bypass and will install soon. Also purchased a new 6.0 cooler to replace stocker but am hesitant to install if tranny is failing because I am concerned that the new cooler will just get some blockage from a potentially failing transmission and I will be buying a new cooler along with a BTS rebuild.
View 14 Replies
My transmission on my 2002 7.3 4x4 is pouring fluid from somewhere above the rear of the pan. I thought it was the pan at first. I pulled it off and replaced the filter. After adding fluid while it was running for 4 or 5 minutes it started pouring again. It's not the pan. It's coming from above the pan somewhere. It won't leak unless it's running. Is there a place it can leak on top??
View 7 Replies
Last couple of days I've been chasing a small oil leak. Finally figured out it's coming from one of the hoses connected to the lower part of the hpop (hpop hose). Leak is coming from the fitting connected to the lower part of hpop. Do I need to replace the whole hose and fitting? Just the fitting? is there a replaceable washer or oring?
View 10 Replies
so got to work today, truck engine light comes on all foward motion stops. Just coasts and idles along. I have 280k on the orig stock trans. I also have dp tuner and did the valve body upgrade along with adding the 6.0 cooler hoping to extend the life of the trans. Reverse works. So i asume I am needinf a new trans. My options are Ford HDr4100 orig 4100, Or BTS built trans. I also pull a toy hauler as well. My question is If I order the BTS can I have a my local shop install it or does it need to be programmed at the dealer. If I get the HD from ford installed will I have to remove the dp tuner chip to get it programmed and also will i need another new valve body replacement.
View 14 Replies
I have a 02 f350 4x4 6 SPD one of my transmission lines has went bad is there anywhere that sales them.
View 1 Replies
So I've been getting a whining sound coming from the transmission area. I checked my transmission fluid and it's nice and pink so I checked my transfer case fluid… It came out like black watery gear oil! How bad is this? I am putting synthetic Dex/Merc back in it. It's got me a tiny bit concerned.
View 9 Replies
I have a 2002 7.3 e350 quigley 4x4 Sportsmobile with 312k miles. 2nd owner. Bought it with 295k miles 2 years ago. From what I gathered the tranny is original.
After reversing at a downhill angle, stopping, and shifting the lever to Drive, the tranny doesn't seem to put Drive in gear and depending on the angle of the slope, the van will roll back or barely creeps forward even with throttle. Put it in 1st gear, and the tranny engages that in gear and drives forward no issues, then I can shift to 2nd, then Drive and the tranny shifts fine after that.
No weird tranny noises or clunking. Noticed this issue about a month ago or about a couple thousand miles ago. Did tranny service (drain, filter, fill) at the ford dealership at 305k months ago.
I can only replicate this issue when Reversing on a down slope. On a flat surface van Reverses and engages Drive like normal.
View 7 Replies
Truck is a 02' F350 xlt crew cab, 7.3l, 4x4, 4R100, manual transfer case, 125,000 miles.
So me and the family were pulling out of the driveway tonight and electrical smoke starts blowing out the vents. My wife had just plugged a cheap USB charger into the auxiliary outlet above the cup holders for only 30 seconds. I immediately pulled back into the driveway, yanked the charger out, and found it had melted a hole in the side of it. No smoke had come from the charger or the outlet. The outlet looked fine and wasn't hot to the touch. I pulled the dash off real fast and started grabbing wires, feeling for anything that was hot or melting. I couldn't find anything.
I pulled the cover off under the steering wheel and couldn't find anything. I never turned the truck off while I was looking. After a few minutes, I noticed that the cover over the fuse panel was warm. Pulled the cover off and felt every fuse end and they were all cool to the touch. The relays in the middle were all pretty warm(almost hot to where I couldn't touch them). I was still faintly smelling the burnt smell and I couldn't tell if it was just stuck in my nose. I disconnected the batteries and we had to switch cars(heading to a bbq).
So I just got home and I'm going to start looking for any obvious signs first. What could be going on at the panel? So far, everything is still working. I haven't found any blown fuses.
View 7 Replies
2002 F350 7.3 PSD. 192k miles.
From my understanding, a CEL is supposed to illuminate each time you turn the ignition ON as part of normal startup procedure.
I figured the previous owner must have pulled out the bulb to hide the fact that the truck had a few "issues" before selling it, so today I pulled out the gauge cluster and it looked as if the CEL bulb was a tiny LED soldered directly into the gauge cluster itself. There were a few serviceable/removable bulbs for things like turn signal indicators, high-beam etc... but the CEL did not have a serviceable/removable bulb.
I've been driving this truck and working through it's "issues" and fixing things as I go, but it keeps throwing codes without the CEL illuminating. What's going on here?
I thought the check-engine-light was supposed to illuminate each time the ignition was turned on, and that it would come on each and every time the vehicle registered a fault code in the ECU/PCM.
View 14 Replies
I have a 03 F-350, 7.3L. There is a slow oil leak that only leaks after I've run the truck. In other words, it doesn't just sit and leak overnight. I'll park it after running, and the next morning I'll notice a small pool of oil, approximately 2" in diameter. The leak appears to be coming from the oil pan area. I degreased the entire oil pan area to get a better visual of where the leak is coming from. I can see oil trailing down the front of the oil pan and the rear of the oil pan. Does this sound like the gasket? Or, what else could it be? I'm praying its not as bad as I think and need to replace the gasket.
View 3 Replies
This was briefly discussed as part of another thread. It appears that I have a boost leak when I hit roughly 24.5 psi. The leak seems to stay for a few minutes after showing itself, but then I'm able to produce boosts up to 24.5 again. For example, on my 20-mile/30-minute drive to work, I can make this leak "appear" four or five times, maybe more if I try. Does this self-healing leak ring a bell? I haven't done a boost leak test yet, but I'm leaning towards the RTV sealant at the OEM plenums due to the self-healing attribute.
To add a little info to this thread, I recently installed an S&B intake, 4" exhaust, bellowed up-pipes, RR billet wheel, RR CAC intercooler boot kit with new clamps, RDP reinforcing plenum inserts, AIH delete plug, and I removed the wastegate solenoid along with the red and green tubes. I don't have any gauges, but I recently began monitoring the boost using FORScan. Before all of this, I don't think I was producing enough boost to cause this leak, and I had no way to monitor for this leak.
View 14 Replies
Brothers of fte. I reach out. Tonight it appears I had a fuel bomb under the hood.
I've been chasing a fuel leak. Replaced fuel drain orings but one screw seemed to not snug up. Also the plastic was so brittle I couldn't replace the inner oring. Installed new valve worked great. A week later noticed new slow drips. Replaced fuel filter. Again good for two weeks.
Tonight pulled into the driveway hopped out immediately smelled diesel. Steaming from under hood. Popped the hood and everything was wet. Moved her to the street and it clattered like I was running out of fuel. Still half a tank though. Hosed of the drive. Popped hood again fired it up easily. Started fine. No noticeable leak. But everything is wet from fuel. Insulation on hood was saturated. When I open the hood fuel ran out of the insulation into the air intake. Batteries were wet!
Alright what gives? Do I have to be under load to see this leak?
View 6 Replies
I've developed a large oil leak in the valley. My guess is the EBPV. What's it take to fix the leak if I DONT remove the valve?
There's a good chance I'll just take it to my works fleet dept and tell them to fix it.
View 7 Replies