Ford 7.3L Power Stroke (1999-2003) :: 2001 - AC Blows Only Through Defrost Vents
Jun 17, 2010
My 01 ac has worked just fine up until today. I got in this morning to leave the house and the air was only coming out of the defrost vents. I tried playing with the controls to get it to switch but couldn't. I assume its a vacuum leak, but where do I need to start looking?
View 14 Replies
Advertisement
My 99' started o blow air only through the defrost vent today, and won't go through any of the other vents. I think this happens when your vacuum pump goes bad or there is a leak, correct? If so, how can I test these to figure out the problem.
View 2 Replies
As the title implies, that is my problem. Can't get the AC to come out of anywhere other than the windshield defrost vents. Y'all ever encountered this before?
View 4 Replies
The floor and defrost vents work. It just stays on defrost when you try to use the dash vents. The actuator seems to be working fine. I can watch the arm move through all the motions. and I cant find ANY vacuum leaks. Yes I looked at the hubs and under the hood. May be moving to alaska and kind of need my heater to work properly. . . .
View 5 Replies
My nav. when I put the air cond on auto and lower the temp so the air comes on, it blows out the vents on the front of the dash like it should and is cold. Then after about 30 seconds give or take, I hear a door deep inside the dash shut, or open, then the cold air only comes out the dash vents that are the defrosters for the windshield.
Then I can make it go back to the front vents again by pushing the button on the heater control to make the cold air come out the front vents again, but then it does the same thing again. Whats going to need to be replaced/repaired?
View 1 Replies
2006 F250 with the dash controlled 4x4. I typically keep the front hubs locked on this truck. I have recently noticed that when shifting into 4x4 that the a/c or heat will switch from blowing out of the vents to blowing out of the defrosters. Any clues how to fix this?
View 1 Replies
Proud new owner of a 2001 7.3....today. The previous owner installed Warn standard hubs. I assume they work same as OEM with the exception that I have to get out and lock them, right? Also, when I test drove it, and after locking them, I engaged to 4x4 button and the 4x4 engaged and worked. However, when I disengaged my AC went to defrost just like my old 7.3. The AC eventually came back. Is this normal? I think it also went to defrost when I engaged. The AC does come back after a couple minutes after disengaging.
View 14 Replies
I have a 2010 f-150. Started having issues with the blend door actuator located behind the radio so replaced that a couple months ago and fixed issue. Now the a/c will only blow through the defrost and floor vents. I replaced the lower blend door actuator thinking that might be the culprit, but did not fix the problem. What the solution might be.
View 3 Replies
So in the past week only on certain days I have lost my ability to change zones for where my nice refreshing cold air blows on me from. It only blows out of the defrost vents. I here a fluttering noise under the dash when this happens. Also under the hood where all the AC hoses and such are located I feel cold air coming from inside the black box just next to what looks like the blower fan assembly. I don't believe I should be feeling that.
View 5 Replies
My wife's '02 Explorer has developed an issue with the heat/AC. As far as I can tell, the heat is hot when it's supposed to be hot, and the AC is cold when it's supposed to be cold. But, the problem is that everything only blows out through the defrost vents, no matter what setting it is on.
I know there are other threads on this type of subject, and I have read a lot of them. I thought I had identified that actuator gizmo as the culprit, but the more I read, it didn't seem like the symptoms for that issue are exactly like mine. I want to try and fix it myself, and I'd love to take the time to read everything on the subject, but warmer weather is here and my wife wants it fixed yesterday!
This problem reminds me of the time the vacuum pump went out on my F-350 and the defrost vents were all that would work. I wish this problem would be as easy to fix as that was.
View 5 Replies
My 2006, King Ranch, 4x4, 6.0's air conditioner only blows from the defrost vent. I have done some research on here, but haven't seen anything that identifies as a common problem. I did however, notice that this problem is stemming from a vacuum issue.
View 10 Replies
My 01 SD won't blow air anywhere but through the defrost vents.
View 9 Replies
No matter what I do with the settings for my heater in my lariat air only blows out of the dash vents. Defrost and floor vents don't work it still blows hot air out of the dash vents. I'm not sure what the deal is maybe the vacuum system? I did a search and all I could find was people having trouble with air ONLY blowing out of the defroster and my case is just the opposite.
View 8 Replies
I have a 2000 450, and the a/c keeps switching to defrost by itself. Any way to fix??
View 14 Replies
My new to me 99 f350 has a great a/c but it only blows on high. Am I looking at a blower motor, resistor, or the fan switch? I'm grateful that it does blow on high being in SE TX and SW LA. If it didn't I couldn't ride in the old girl. A black truck with no a/c is not happening this time of year....
View 12 Replies
Air is only blowing through the defrost vents. No matter what I do - try to turn vents, A/C, heat, fresh air, recirculating, etc. Assume it's a switch or fuse issue somewhere. How to fix it?
View 11 Replies
I have Warn hubs that I have to lock in. All works good. A/C goes to defrost at first when cranking but then runs fine after a couple seconds. So, I was thinking that maybe my pump is running all the time. Who knows. I'm sure all my vacuum lines are dry rotted. What exactly is the need for it exactly and what's the best way to cap? Hoping to do it at the unit itself if possible.
View 6 Replies
After some diag I got the A/C to blow out the front vents. There are million threads on this issue half of them are never figured out. This is the second time I have come across this problem so will make this really informative for those who have this problem. If you A/C blows to defrost, yes most of the time its going to be a vacuum leak issue.
Step 1) turnkey on engine off, stand by passenger fender and listen.. can you hear the pump running? If it is your pump isn’t dead.
Step 2) does the pump run for 30 seconds then shut off? You may not have a vacuum leak. If keep’s running for ever you have a leak. Inspect all lines, especially those going down to the hubs for cracks. Also inspect vacuum lines under passenger glovebox.
Step 3) can’t find a leak? Disconnect the line going to the ESOF solenoid and plug it, if you pump stops running then your ESOF solenoid has an internal leak. That was my problem 6 months ago, replaced ESOF, A/C blows normally.
Try This Second! So my AC isn't blowing through my front vents again.... (more diag)
AC not blowing through vents and can’t find a vacuum leak? Take off glove box door, turn AC control switch to floor/defrost/front vents, watch the metal arm connected to the side of the big black box move up and down into various positions. I noticed on mine the arm will go down in positions (floor or defrost) But it will not move up! Which needs to happen to switch to front vents. If I push the rod up by hand manually, the ac will blow through front vents, and stay blowing through front vents even after I let go. PIC of metal arm thing connected to diaphragm, which changes air flow by moving flap inside the big black box
I am guessing the Diaphragm is the issue? The truck will continue to blow from the front vents even when the truck is shut off and restarted, it will stop when I switch the ac to a different position, it will not return back to front vents.
View 7 Replies
All vacuum lines are good, pump works, Canister isn't leaking, 4x4 activates and I can feel it, so Can't be vacuum leak. Replaced esof solenoid 6 months ago last time this happened, but this issue seems to be different. Watch this vid I made showing the issue.. after viewing video, do yall' agree I isolated the issue? If that one tug makes the air go through the front vents, that means everything else in the A/C mode selection works..
YouTube.....
View 2 Replies
I have an 03 F250 7.3litre. I have noticed the last few times driving while hauling that my vents start pushing hot air when under a load (example: driving up a long, steep pull) even if I have the AC on. It's starting make me a lot hot under the collar (pun intended) .....
View 14 Replies
I noticed a couple weeks ago after starting the truck and turning on the a/c that nothing was coming out of the vents. I found it odd when after driving a few miles the a/c kicked in and started blowing cold air. Today I needed to put on the defrost and same thing, nothing came out of the vents. I drove around for a while hoping it would kick in just like the a/c did but nothing. I did check the fuses and relay. When you turn the control either to heat or a/c you can hear a clicking sound under the hood. It's trying to engage but nothing is coming out of the vents.
View 12 Replies