Ford 6.0L Power Stroke Diesel :: 2006 F250 - Gear Shifting Seems Very Loose
Jun 14, 2016
My truck just started to have issues with the gear shift. The gear shift seems very loose now and it is having trouble getting back into the park position. Is this a larger transmission issue, or is possibly a failing part on the actual shift mechanism?
View 3 Replies
Advertisement
I have a 2006 f250 6.0L with 76,000 miles on it. And it just started to shift softer then normal under light throttle. The first to second to third shift are softer then normal. And the third to fifth gear shift seems to have a lot of what I would call overlap and some times it feels like it is slipping. Gets better under hard acceleration but not as firm as it used to be. I have always changed the trans fluid and filter every 25,000 miles. Trans temp runs about 150 to 160deg. I checked the fluid today and it's bright red and does not smell bad. And I don't have any coeds. Could it be a solenoid going bad ?
View 9 Replies
I currently have a 2006 F-250 6.0 with 187,XXX.
My problem that i am having is that the transmission recently within a couple weeks started acting weird about the same time 3 of my fuel injectors started failing. When i start up the truck and put it into drive it takes about 3-5 seconds to shift. Once it's in drive it runs pretty well but it will start shifting out of normal when i go to accelerate. Also when i go to slow down sometime the transmission shifts hard to a lower gear. I also have a video of the sound that it had started to make since its hard to describe.
Here are attached videos and photos. I want to hopefully fix the problems myself so i can learn more about my truck. I am going to handle the fuel injectors here soon since 2 are failing and ones about to these have been causing the truck to shudder at around 47-53 mph but after that its fine.
The transmission is stocked and never been altered, i do admit for 3-4 years I have changed the fluids or filters.
The truck is bullet proofed, sct tuner, upgraded turbo from stock, 4" exhaust, head studs and new everything when the engine was rebuilt and bulletproofed.
I plan on going to ford tmw to have them figure out the problem and hopefully its just solenoids so i can fix it myself. I have a link posted also where you can hear the noise it has been making when in R P and when shifting going down the road and it is a automatic.
YouTube.....
View 14 Replies
I have a 2005 f250 6.0 diesel. I have changed the 2 fuel filters, fuel pump, sending unit (was broke off in tank )and installed the blue spring fuel pressure regulator kit. My truck will run for a few minutes loose fuel and kill. Could this be a sensor or computer problem
View 12 Replies
Transmission was not shifting out of second gear set a code stuck solenoid cleared code seems to be working now....
View 4 Replies
When the truck shifts into 5th gear i instantly feel a constant vibration and noise until it shifts to 6th gear. This happens nearly every time while driving at 40mph. Rpm range 1200 - 2000. I bought the truck new on June 30th and noticed the problem on my way to work on Monday July 2nd. Took it to the dealer on July 5th and the tech said it was the torque converter slipping. I drove it home because they didn't have time to work on it. Took it back on July 12th and the dealer has had it since (currently 30 days) They originally told me it was not the engine or transmission and it was an exhaust problem. Last week they said it was the motor mounts and said they would be done.
View 14 Replies
This is is a truck I hardly know anything about. My wife bought it while I was deployed for herself and when it comes to vehicles she's an idiot. No, really she told me she bought it because at horse shows everyone else has one.
I noticed an oil leak and had a reputable shop look at it. They told me it was coming from some seals on the turbo. Long story short there is a brand new turbo on there, stock replacement. Now it seems very under powered and shifts hard. Pressing down anything more than 25% throttle will cause hard shifting or no shifting at all. It'll stay in second until I ease off the throttle.
I tried searching a few terms but I'm not sure what to look for. I don't know if someone has messed with the tuning. Broken clamp on the turbo. Replaced and everything is back to normal...
View 4 Replies
2005 F250 4X4 6.0 .. Why my truck just stopped going when put in gear and the TOW/HAUL light just kept coming on, without pushing it 2 days prior? Now it will not go anywhere, starts great, gas pedal works because RPM's go up when pushing! Just will not go when put in drive or reverse! What else I can do? I replaced cylinoid B in the transmission, speed sensor, and brake switch.
View 14 Replies
I recently bought a 2005 F250 4x4 automatic trans with 177,000 miles. In the last 300 or so miles it has developed a whine from under the truck like gears not meshing. It is constant and only the speed of the truck seems to affect the volume of it. It is loudest, considerable louder, on deceleration. Different gears have no effect, 4x4 high or low has no effect, even slipping it into neutral while its rolling has no effect. I have seen various websites about bad wheel bearings, transfer cases, and rear end gears causing this type of noise. There is no vibrations, slipping, shuttering, at anything else unusual. Except for noise it drives ad rides completely normal.
View 2 Replies
I have a 04, f-250, with a 6.0 liter engine. I have had the Cat removed and in the last couple months it has developed a sneeze like hesitation just before it down shifts to Passing gear, If I push my foot into the fuel it jumps right down thru the sneezing into passing gear. I have changed fuel filter and grade A cleaned my EGR valve. the only Codes it throws is P0403 and P0405.
View 10 Replies
My 2006 F250 was towing my 5th wheel when it started to loose power and eventually died. Would not restart. Replaced all fuel filters to no avail. Towed to mechanic shop. Has a little over 100,000 miles on it. Waiting for mechanic to check it out.
View 3 Replies
I have an 06 F-250 with 122,000 miles. When driving empty at 70-75 mph the coolant temp runs 194-200 and the oil temp 5 to 10 degrees higher at the most. When I pull my travel trailer the coolant temperature will start to steadily climb then abruptly drop down under 200. I have seen the coolant temperature pass the oil temperature when this happens.
The last time I pulled the trailer I was driving at 60 mph and the coolant temperature climbed to 220 then dropped to 196. A few miles later it climbed to 230 then dropped to 200. While the temperature was climbing I slowed to about 45 mph. As it was dropping I accelerated and the temperature continued to drop.
I have flushed the cooling system, replaced the thermostat and cap with no improvement.
The pickup has an SCT tuner set to street 1 and I was told by the previous owner that the egr was deleted, but the stock egr cooler is in place. It is possible that a plug was put in. I pulled the egr valve and the carbon coating on it is gooey like it has been wet.
View 12 Replies
My 2006 F-250 6.0PSD has a new hitch. Tonight it would not start once hot. It cranked and cranked but no start. My scanner showed ICP readings of 366PSI during cranking. Far below the 500PSI needed before the computer will fire the injectors.
So is this the STC fitting at the HPOP that is failing? If so how long will she start cold and drive normal before she leaves me stranded? I have the fittings and new dummy plugs and stand pipes as well. I was waiting to to do this work until I had the money for an new EGR cooler and oil cooler.
I know my oil cooler is failing as my deltas are showing a 15-19 degree spread over my coolant temps.
View 14 Replies
I have a 2006 f250 6.0. the truck has 101k miles and to this point I have had zero issues. I am having trouble loosing power after running at highway speeds. Once I stop and begin to accelerate the truck looses power for a few seconds ,Belches smoke and begins to operate normally. I had an egr code, so I replaced egr and the problem persist. It is intermittent and does not happen if I stay under 50 mph.
View 12 Replies
So today on my way home from work. I got off at my exit and when I went to step on the gas I lost power and the truck wouldn't exceed 15 mph. It would just rev up and down. It was pouring white smoke from the tailpipe. At one point it went back to normal and started running fine for about 10 seconds. Then it went back to doing the same thing losing power and spitting smoke. I limped the truck into a parking lot and called a ride. I'm having a tow truck pick it up on Monday and take it to the dealership. Is this a head gasket issue? And I feel like it's going to be expensive. 2006 F250 6.0L .....
View 11 Replies
I have a 2006 f250 superduty 6.0. The truck ran fine a week ago and than died as I was going to take it for a drive. I figured out that the fuel pump (air dog system) was not working. I fixed that and primed the pump. The truck still won't start. When it first happened the truck would crank but not start. Now all I hear is the starter but no cranking. Both filters could be replaced. The bowl to the upper is dry when I take the cap off. However fills up when you turn the key on. I'm not sure what else to try and I need to get this truck started.
View 3 Replies
I have a 2006 f250 bulletproofed for about 5 years now with no problems other than normal wear and tear. I had the factory water pump go out a couple months ago so I decided to go with the bulletproof diesel pump for piece of mind now I do tow anywhere from 8K-15K about once a week with custom Gearhead tunes using SCT.
While I was changing water pump, I ordered low temp thermostat figured it would work with towing temps even though they weren't that bad to begin with my deltas always around 10-128.. Now i am seeing signs of puking out degas bottle, I replaced cap seems to work a little the truck doesn't puke unloaded unless i really get down on it.
I noticed the other day while towing I was cruising with TC locked in at around 55 mph and i watched my EOT 210* and ECT 205*, the n ECT started climbing up followed by EOT then at ECT 222* fan came on ECT finally hit 234* and started dropping fast while EOT never got over 226*. ECT would level out at 188* go back up to 205* and stay there for awhile and do it all over again...
What is going on. I've talked to a could mechanics and they aren't confident its the HG..
View 14 Replies
I have a 2006 Ford F-250 6.0 powerstroke with 100,000 miles and it puts out a puff of smoke at cold start up every time and also when I run it then park it for maybe 1 1 1/2 and it puts out a puff and also I noticed when I get to work with is about a 20 minute drive I get there around 8 then leave at 5 I noticed it puts out a puff then if I watch the exhaust I can see a slight haze but I figured it's just condensation.
Here's the list of stuff I have put on the truck... Oringed heads by librator performance, with oem gaskets every thing, arps head studs, egr delete, airdog 2 fuel system,mtw stage 2 turbo, bulletproof ficm,coolant filter, banks intake, fuel pressure set at 68 and fuel regulator return.
Here's a list off parts I put on trying to fix the smoke I put in 5 injectors because the ford ids had a slight change and after that it was straight line I put in hpop and turbo drain pipe and I tested the ficm and its 48 with the key on and cranking and running...
View 14 Replies
I have a 2006 F250 6.0 with 218xxx on it. Have had a ton of issues since day one, but I finally thought I had gotten a handle on all of them until the other day. Truck started sounding a little rough, no noticeable effect on performance, no codes on my Edge CTS (except one random CKP sensor code that went away). Was leaving work later that day to go home and it started up fine.
Got about a 1/4 mile from the shop and went to turn onto a busier road so I put into the pedal a little bit. Truck immediately lost power. Sounded like a turbo boot blowing and I had very little throttle response. Immediately pulled over and checked codes with truck still on, nothing. Got out and popped the hood with the truck still idling to check for CAC tube/boot etc. As I was looking at it, the engine started screeching. I shut it off as quick as I could get back to the cab.
Looked over everything, nothing noticeably wrong. Went to crank it to see what it would do. All i got was a noise from the starter engaging. Belt not turning over. Tried unplugging the fan clutch (read a thread with similar symptoms and that was the issue for them), connected the starter solenoid directly to battery, same issue. Removed belt and attempted to crank. Same thing. Removed all glow plugs to check for hydrolock. Motor slowly would turn with belt still removed and no glowplugs. Removed starter and tested outside of vehicle, solenoid and motor both seem to be ok.
View 11 Replies
I have an 06 F-250 super duty with 26000 miles.. Was wondering if i need to change my air filter or wait awhile longer. It doesn't look bad but have never seen a filter quite like that one either..
View 12 Replies
I have been dealing with a oil leak for quite some time now, oil seeping from what appears to be around the cam sensor. About a year ago I pulled the cam sensor replaced the o rings that were cracked and split out figured that was my problem. drove it for another year continued to have same seeping oil leak. cleaned it up real good dyed the oil and checked again and seems to be same issue same spot around cam sensor. Pulled it again o rings are perfect but it seems as if that is where the leak is seeping from based off the uv dye I used. is there something else right around the cam sensor that I am missing that could be the cause? I have checked ipr, crank, dip stick, hpop cover, valve cover, glow plugs, a few other spots and have found no other leaks from any other than around that came sensor.
2006 F250 6.0 King Ranch
View 10 Replies